Standards:
FM Class 3600: 2011, FM Class 3610:2010, FM Class 3810:
2005
Markings:
IS Class I/II/III, Division I, Groups A, B, C, D, E, F, and G, T4;
Class I, Zone 0 AEx ia IIC T4; Ga T4 (-50 °C ≤ T
a
≤ +70 °C)
8.6.2 N5 CSA Class 1 Division 2 (USA)
Certificate:
1143113
Standards:
FM Class 3600: 2011, FM Class 3611: 2004, FM Class 3810:
2005
Markings:
Class 1, Division 2, Groups A, B, C, and D, T5(-50 °C ≤ T
a
≤ +85
°C); Class II, Division 1 Groups E, F, G, T5(-50 °C ≤ T
a
≤ +85 °C);
Class III; Also include use in Cl, I, Zone 2, IIC, T5.
Special Condition for Safe Use (X):
See 00702-1020 for installation requirements.
8.7 Canada
8.7.1 I6 CSA Intrinsically Safe (Canada)
Certificate:
1143113
Standards:
CAN/CSA-60079-0-:2015, CSA C22.2 No. 94.2-07, CAN/CSA-
C22.2 No. 61010-1-12, CAN/CSA C22.2 No. 60079-11:14,
CSA Std C22.2 No. 60529:16
Markings:
Intrinsically Safe Class I, Division 1, Groups A, B, C and D, T4;
Ex ia IIC Ga Type 4X
8.7.2 N6 CSA Class I Division 2 (Canada)
Certificate:
1143113
Standards:
CAN/CSA-60079-0-:2015, CSA C22.2 No. 94.2-07, CAN/CSA-
C22.2 No. 61010-1-12, CSA C22.2 No. 213-2017, CSA Std
C22.2 No. 60529:16
Markings:
Suitable for Class 1, Division 2, Groups A, B, C, and D, T5; Cl. I,
Zone 2, IIC, T5
Special Condition for Safe Use (X):
See 00702-1020 for installation requirements.