Deltabar PMD75B PROFINET with Ethernet-APL Operation options
Endress+Hauser 31
7.4 local display
7.4.1 Device display (optional)
Functions:
Display of measured values and fault and notice messages
Background lighting, which switches from green to red in the event of an error
The device display can be removed for easier operation
In the dual compartment, L-form housing, the device display fits into both housing parts
(top and side).
The device displays are available with the additional option of Bluetooth® wireless
technology.
1
4 5
6
7 8
2
3
A0047143
 4 Segment display
1 Measured value (up to 5 digits)
2 Bar graph (not for PROFINET with Ethernet-APL)
3 Unit of measured value
4 Locked (symbol appears when the device is locked)
5 Bluetooth (symbol flashes if Bluetooth connection is active)
6 communication via PROFINET is active
7 Has no function in the case of PROFINET with Ethernet-APL
8 Measured value output in %
The following graphics are examples. The display depends on the display settings.