EasyManua.ls Logo

Endress+Hauser Deltabar S FMD 77 - Page 25

Endress+Hauser Deltabar S FMD 77
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Deltabar S
Endress+Hauser 25
FMD 76 (with ceramic measuring diaphragms)
PMD 75 (with metallic measuring diaphragms)
FMD 77 (with metallic measuring diaphragms)
Versions in the order code Seal Temperature operating range
1
1) Seal for lower temperatures on request
B, D, F, G, U FKM Viton, Compound VC601 –4 to +185°F (–20 to +85°C)
K, L EPDM, Compound E7502,
FDA 21 CFR 177.2600
–4 to +185°F (–20 to +85°C)
M, N Kalrez, Compound 6375 +41 to +185°F (+5 to +85°C)
P, Q Chemraz, Compound 505 –4 to +185°F (–20 to +85°C)
S FKM Viton, degreased,
Compound V80G2
+14 to +185°F (–10 to +85°C)
T FKM Viton, cleaned for oxygen service,
Compound V80G2
+14 to +140°F (–10 to +60°C)
Versions in the order code Seal Temperature operating range
A FKM Viton,
Compound 37559 FPM 90 GLT green
–4 to +185°F (–20 to +85°C)
C PTFE, GF25 –40 to +185°F (–40 to +85°C)
1
1) A lower temperature application limit of +14°F (–10°C) applies to measuring cells with PN 420.
FNBR,
Compound NB 3431/N7003/N7083
–4 to +185°F (–20 to +85°C)
H Copper –40 to +185°F (–40 to +85°C)
1
K Copper, cleaned for oxygen service –40 to +140°F (–40 to +60°C)
1
1 FKM Viton, degreased, Compound V80G2 +14 to +185°F (–10 to +85°C)
2 FKM Viton, cleaned for oxygen service,
Compound V80G2
+14 to +140°F (–10 to +60°C)
3 PTFE, cleaned for oxygen applications,
GF25
–40 to +140°F (–40 to +60°C)
1
Versions in the order code Seal on the LP side (–) Temperature operating range
B, D, F, G FKM Viton,
Compound 37559 FPM 90 GLT green
–4 to +185°F (–20 to +85°C)
H, J PTFE, Compound GF25 –40 to +185°F (–40 to +85°C)
K, L EPDM, Compound E7502 –40 to +185°F (–40 to +85°C)
M, N Kalrez, Compound 6375 +41 to +185°F (+5 to +85°C)
P, Q Chemraz, Compound 505 –4 to +185°F (–20 to +85°C)
S FKM Viton, degreased,
Compound V80G2
+14 to +185°F (–10 to +85°C)
T FKM Viton, cleaned for oxygen service,
Compound V80G2
+14 to +140°F (–10 to +60°C)