Deltabar S
Endress+Hauser 33
Device height H, devices with flange
Hygienic connection, sanitary tank spud
P01-FMD76xxx-06-09-xx-xx-002
Process connection FMD 76, version 5, high-pressure side: sanitary tank spud, extended diaphragm seal 2",
low-pressure side: connection 1/4"-18 NPT, material AISI 316L
Device height H
Process connections
FMD 77 (with metallic
measuring diaphragms), low-
pressure side
P01-FMD77xxx-06-xx-xx-xx-000
Low-pressure side: connection 1/4"-18 NPT, mounting optionally 7/16"-20 UNF, high-pressure side, see the following
section "Process connections, high-pressure side FMD 77"
Description Device height H (h + b)
Housing, optional display on the side 6.89" (175 mm) + flange thickness b (see tables)
Housing, optional display on the top, flat cover 7.12" (181 mm) + flange thickness b (see tables)
Housing, optional display on the top, high cover 7.56" (192 mm) + flange thickness b (see tables)
2.11”
(53.5)
4.39”
(111.5)
H
ø3.60”
(91.45)
ø3.94”
(100)
ø5.22”
(132.7)
Description Device height H
Housing, optional display on the side 10.1" (257 mm)
Housing, optional display on the top, flat cover 10.4" (263 mm)
Housing, optional display on the top, high cover 10.8" (274 mm)
5.91”
(150)
4.08”
(103.7)
+
–
3.94”
(100)
1.63”
(41.3)
7/16”-20 UNF
1/4”-18 NPT
Note: DP ceramic cell not resistant to caustics.