Deltabar S
58 Endress+Hauser
FMD 76
→ For continuation of FMD 76 ordering information, see the following page.
10 Certificates
A For non-hazardous areas
1 ATEX II 1/2 G EEx ia IIC T6
6 ATEX II 1/2 G EEx ia IIC T6, overspill protection WHG
2 ATEX II 1/2 D EEx ia IIC T6
3 ATEX II 1/2 GD EEx ia IIC T6
4 ATEX II 1/3 D
7 ATEX II 3 G EEx nA II T6
S FM IS, Class I, II, III Division 1, Groups A – G; NI Class I Division 2, Groups A – D; AEx ia
R FM NI, Class I, Division 2, Groups A – D
U CSA IS, Class I, II, III Division 1, Groups A – G; Class I Division 2, Groups A – D, Ex ia
20 Electronics, communication, display, operation
A 4 to 20 mA, HART, LCD, external push buttons (→ see Fig. 1, 2)
B 4 to 20 mA, HART, LCD (→ see Fig. 1, 3)
C 4 to 20 mA, HART (→ see Fig. 3)
M PROFIBUS PA, LCD, external push buttons (→ see Fig. 1, 2)
N PROFIBUS PA, LCD (→ see Fig. 1, 3)
OPROFIBUS PA (→ see Fig. 3)
P Foundation Fieldbus, LCD, external push buttons (→ see Fig. 1, 2)
Q Foundation Fieldbus, LCD (→ see Fig. 1, 3)
R Foundation Fieldbus (→ see Fig. 3)
30 Housing, Cable entry, Protection
A Aluminum T14 housing, optional side-mount display, M 20x1,5, IP 66/67/NEMA 6P
B Aluminum T14 housing, optional side-mount display, G 1/2, IP 66/67/NEMA 6P
C Aluminum T14 housing, optional side-mount display, 1/2" NPT, IP 66/67/NEMA 6P
D Aluminum T14 housing, optional side-mount display, M 12x1 PA plug, IP66/67/NEMA 6P
E Aluminum T14 housing, optional side-mount display, 7/8" FF plug, IP 66/67/NEMA 6P
F Aluminum T14 housing, optional display on the side, Han7D plug, 90 deg.,
IP 65/NEMA 4X
J Aluminum T15 housing, optional top-mount display, M 20x1,5, IP 66/67/NEMA 6P
K Aluminum T15 housing, optional top-mount display, G 1/2, IP 66/67/NEMA 6P
L Aluminum T15 housing, optional top-mount display, 1/2" NPT, IP 66/67/NEMA 6P
M Aluminum T15 housing, optional top-mount display, M 12x1 PA plug, IP 66/67/NEMA 6P
N Aluminum T15 housing, optional top-mount display, 7/8" FF plug, IP 66/67/NEMA 6P
P Aluminum T15 housing, optional top-mount display, Han7D plug, 90 deg.,
IP 66/67/NEMA 4X
1 AISI 316L T14 housing, optional side-mount display, M 20x1,5, IP 66/67/NEMA 6P
2 AISI 316L T14 housing, optional side-mount display, G 1/2, IP 66/67/NEMA 6P
3 AISI 316L T14 housing, optional side-mount display, 1/2" NPT, IP 66/67/NEMA 6P
4 AISI 316L T14 housing, optional side-mount display, M 12x1 PA plug, IP 66/67/NEMA 6P
5 AISI 316L T14 housing, optional side-mount display, 7/8" FF plug, IP 66/67/NEMA 6P
6 AISI 316L T14 housing, optional side-mount display, Han7D plug, 90 deg., IP 65/NEMA 4X
Z Housing: see additional specifications
1
Display
Damping
off
on
[]
Sensor
Histo
ROM
2
1
PC
3
2
T15
T14
40 Measuring cell, nominal operating range, PN
7D 40 inH
2
O measuring cell, PN 16 (100 mbar/10 kPa/1 mH
2
O/1.5 psi)
7F 200 inH
2
O measuring cell, PN 100 (500 mbar/50 kPa/5 mH
2
O/7.5 psi)
7H 1200 inH
2
O measuring cell, PN 100 (3 bar/300 kPa/30 mH
2
O/45 psi)
50 Calibration, units
1 Calibration: nominal range, mbar/bar
2 Calibration: nominal range, kPa/MPa
3 Calibration: nominal range, mmH
2
O/mH
2
O
4 Calibration: nominal range, in H
2
O/ftH
2
O
6 Calibration: nominal range, psi
B Custom calibration: see additional specification
C Factory calibration: see additional specification, Factory calibration certificate, 5-point
D DKD calibration: see additional specification, DKD-Certificate
K Calibration: see additional specification, PLATINUM
L Factory calibration: see additional specification, PLATINUM,
Factory calibration certificate, 5-point
M DKD calibration: see additional specification. PLATINUM, DKD-Certificate
FMD 76 complete order code