10 Technical Data Temperature head transmitter
52 Endress+Hauser
10 Technical Data
Operation and system construction
Measurement principle Electronic measurement and conversion of input signals in industrial
temperature measurement.
Measurement system The iTEMP
®
HART
®
TMT 182 temperature head transmitter is a 2 wire
transmitter with an analogue output. It has a measurement input for resist-
ance thermometers (RTD) in 2-, 3- or 4-wire connection, thermocouples and
voltage transmitters. Setting up of the TMT 182 is done using the HART
®
-
Protocol with hand operating module (DXR 275) or PC (COMMUWIN II).
Input values
Measurement value Temperature (temperature linear), resistance and voltage.
Measurement range Dependent on the sensor connection and input signal, the transmitter
evaluates a number of different measurement ranges.
Type of input
Resistance thermometer
(RTD)
Type Measurement ranges
min.
meas.
range
Pt100
Pt500
Pt1000
acc. to IEC 751
-200 to 850 °C(-328 to 1562 °F)
-200 to 250 °C(-328 to 482 °F)
-200 to 250 °C(-328 to 482 °F)
10 K
10 K
10 K
Ni100
Ni500
Ni1000
acc. to DIN 43760
-60 to 250 °C (-76 to 482 °F)
-60 to 150 °C (-76 to 302 °F)
-60 to 150 °C (-76 to 302 °F)
10 K
10 K
10 K
• Connection type: 2-, 3- or 4-wire connection
• Software compensation of cable resistance possible in the 2 wire system
(0...30
Ω)
• Sensor cable resistance max. 11
Ω per cable in the 3 and 4 wire system
• Sensor current:
≤ 0.2 mA
Resistance transmitter Resistance (Ω)
10... 400
Ω
10...2000 Ω
10 Ω
100 Ω