Mounting Levelflex M FMP40 FOUNDATION Fieldbus
16 Endress+Hauser
Coax probes
The shortening is necessary if the distance to the container floor or outlet cone is less than 10 mm.
Coax probes can be shortened max. 80 mm from the end. They have centering units inside which
fix the rod centrally in the pipe. The centerings are held with borders on the rod. Shortening is
possible up to approx. 10 mm below the centering.
3.4.3 Mounting probes in an empty silo
"
Caution!
If there is a risk of electrostatic discharge from the product, then both processconnection and rope
must be earthed before the probe is lowered into the silo.
Levelflex can be screwed into a threaded socket or flange. Proceed as follows:
Insert probe
• Uncoil rope and lower it slowly and carefully
into the silo.
• Do not kink the rope.
• Avoid any backlash, since this mightdamage
the probe or the silo fittings.
!
Note!
For flange mounting: if a seal is used, be sure to
use unpainted metal bolts toensure good
electrical contact betweenprobe flange and
process flange.
L00-FMP4xxxx-17-00-00-en-056
Uncoil rope and lower
probe slowly and
carefully into the silo
Screw down
• Screw the Levelflex into the process
connection or to flange.
• Maximum permissible torque:
– G3/4" : 45 Nm
– G1-1/2" : 450 Nm
When using an aramid fibre seal and a process
pressure of 40 bar:
– G3/4" : 25 Nm
– G1-1/2" : 140 Nm
• Levelflex functions in metal, concrete and
plastic silos. When installing inmetal silos,
take care to ensure goodmetallic contact
between the processconnection and silo.
L00-FMP4xxxx-17-00-00-en-057
Screw in Levelflex
housing allignable
Tighten with the
hexagonal nut only