Diagnostics and troubleshooting Liquistation CSF34
174 Endress+Hauser
Date Version Changes to firmware Documentation
04/2013
07/2013
01.04.00 Extension
Conductivity:
Measuring range switching
Temperature compensation ISO 7888 at 20 °C
Support for DIO module
Triggering of an external hold
Triggering of a cleaning
Limit switch signals via digital output
Keylock with password protection
PID controller: Feedforward control is supported
pH:
Icon for manual and automatic temperature
compensation (ATC/MTC+MED)
Monitoring for the upper and lower limits of the glass
SCS value can be switched on or off independently of
the other respective value
ISE
Simultaneous calibration of two parameters
User-defined electrode type
Raw measured values can be selected for current
output
Timer for membrane replacement
Logbooks are preserved after the firmware update
Improvement
PROFIBUS address range for Siemens-S7 moved to lower
range.
Offset icon only for pH or ORP
Turbidity: Autoranging can be switched off
Export Print (xml): Export file revised and style sheet
added for better legibility.
Original firmware
BA00444C/07/EN/16.13
BA01225C/07/EN/01.13
BA00445C/07/EN/16.13
BA01227C/07/EN/01.13
BA00450C/07/EN/16.13
BA00450C/07/EN/17.13
BA00451C/07/EN/15.13
BA00451C/07/EN/16.13
BA00486C/07/EN/01.11
BA00486C/07/EN/02.13
06/2012 01.03.01 Improvement
Hold via soft key
Global or channel-specific hold stops automatic cleaning.
Manual cleaning can be started, however.
Adapted factory settings
BA00444C/07/EN/15.12
BA00445C/07/EN/15.12
BA00450C/07/EN/15.12
BA00451C/07/EN/14.11
BA00486C/07/EN/01.11
12/2011 01.03.00 Extension
Max. 8 sensor channels supported
Current inputs
PROFIBUS DP supported incl. Profile 3.02
Modbus RTU (RS485) supported
Modbus TCP supported
Integrated web server supported via TCPIP (RJ45)
USP/EP (United States Pharmacopoeia und European
Pharmacopoeia) and TDS (Total Dissolved Solids) for
conductivity
Icon for "controller active" in measuring screen
Improvement
Controller hold via analog input
Adapted factory settings
SAC: factory calibration in the field incl. reset filter
operation time and lamp change
ISFET leak current visible in measuring screen
Multiselect for limit switch and cleaning cycles
BA00444C/07/EN/14.11
BA00445C/07/EN/14.11
BA00450C/07/EN/14.11
BA00451C/07/EN/14.11
BA00486C/07/EN/01.11