Distance offset (2309)
Navigation Expert → Sensor → Level → Distance offset
Write access Maintenance
Description Definition of the distance offset
Input range -200.000,0 ... +200.000,0 mm (-60 ... +60 ft)
Factory setting 0.0 mm
Additonal Information The value speicified in this parameter is added to the measured distance between the
reference point of the measurement and the level echo.
• Positive values increase the distance and thus decrease the level.
• Negative values decrease the distance and thus increase the level.
A0016081
2 Effect of the "Distance offset" parameter
ΔD Distance offset
D0 Measured distance (as indicated in "Expert → Sensor → Distance → Distance")
D Corrected distance (is used to calculate the level)
R Reference point
A value entered into this parameter is taken into account in the calculation of the
level. However, it does not influence the indicated distance.