Micropilot FMR50/FMR51/FMR52/FMR53/FMR54/FMR56/FMR57 FOUNDATION Fieldbus The "Expert" menu
Endress+Hauser 107
3.2.14 Expert → Sensor → Tank bottom evaluation
Overview
The tank bottom evaluation is intended to prevent an echo loss if the tank is empty.
A [dB]
4
5
4
D [m (ft)]
2
3
1
A0020631
1 Tank/silo height
2 Tank bottom range
3 Min. amplitude TBD
4 Lower level area
5 Tank bottom echo
I no echo is found within the defined tank height (Tank/silo height parameter
4)
), the
tank bottom searches beyond this distance in the Tank bottom range to see whether an
echo from the tank bottom exists.
If a tank bottom echo has been found, a level of 0% is assumed. If neither a direct level
echo nor a tank bottom echo has been found, an echo loss is reported (error message
S941).
Level echoes from within the measruing range always have a higher priority than
the tank bottom echo.
The first echo factor is not applied to the tank bottom echo.
Parameters of the "Tank bottom evaluation" submenu
Parameter Meaning Description
Tank bottom range Defines the range below Tank/silo height in which a tank bottom echo is
searched for if no direct level echo has been detected.
(→  108)
4) Navigation path: Expert → Sensor → Level → Tank/silo height