Installation Micropilot FMR56, FMR57 FOUNDATION Fieldbus
32 Endress+Hauser
6.4 Container with heat insulation
1
2
A0032207
If process temperatures are high, the device should be included in the usual container
insulation system (2) to prevent the electronics from heating as a result of thermal radiation
or convection. The insulation should not be higher than the neck of the device (1).
6.5 Turning the transmitter housing
To provide easier access to the connection compartment or display module, the transmitter
housing can be turned:
max. 350°
8 mm
8 mm
1.
2.
3.
A0032242
1. Unscrew the securing screw using an open-ended wrench.
2. Rotate the housing in the desired direction.
3. Tighten the securing screw (1.5 Nm for plastic housing; 2.5 Nm for aluminum or
stainless steel housing).