To check that values are displayed correctly, the following string appears on the device display
or operating tool: 0123456789+-.
5. The user must confirm that the values are displayed correctly.
The device displays the current settings for the following parameters one after
another for the user to confirm each of them:
Failure mode
Installation
direction
Current span
4 mA value
20 mA value
Damping
Flow damping
Pressure shock
suppression
Assign
low flow cutoff
Off value
low flow cutoff
On value
low flow cutoff
Filter option
Signal mode
A0031492-EN
For detailed information on the parameters in the graphic, see the Operating
Instructions.
6. At the end of the verification, the SIL locking code 7452 must be entered in the Set
write protection parameter again to confirm that all the parameter values have been
defined correctly.
If the SIL locking code has been entered correctly, the message "End of sequence"
appears on the display.
7. Press the key to confirm.
The SIL mode is now activated.