Proline Promag 300 HART Design
Endress+Hauser 13
NOTICE
Use the measuring device according to the specifications.
‣
Pay attention to the medium properties and the environmental conditions.
‣
Carefully follow instructions pertaining to critical process situations and installation
conditions.
Detailed information on:
• Mounting
• Electrical connection
• Medium properties
• Environment
• Process
Operating Instructions → 10
L
CAUTION
For liquids that readily boil or in the case of suction lines:
‣
It is the responsibility of the user to assess the influence of the process conditions and the
medium on the measurement result in safety equipment, particularly the occurrence of
changes in the magnetic system due to external magnetic fields or deposit buildup.
‣
Ensure that the vapor pressure is not undershot and that the liquid does not start to boil.
‣
Please ensure that there is never any outgassing of the gases naturally contained in many
liquids. Sufficiently high system pressure prevents the occurrence of these effects.
‣
In order to guarantee correct measurement, ensure that no cavitation occurs.
Further information on the suitability of the measuring device for safety-related
operation is available from your Endress+Hauser sales center.
4.2 Marking
SIL certified devices are marked with the SIL logo on the nameplate.