Proline Promag 300 HART Design
Endress+Hauser 11
Measuring device Documentation code
Promag H 300 BA01392D
Promag P 300 BA01393D
Promag W 300 BA01918D
4 Design
4.1 Permitted device types
The information on functional safety contained in this manual relates to the device versions
listed below and are valid as of the specified software and hardware version.
Unless otherwise specified, all subsequent versions can also be used for safety functions.
A modification process according to IEC 61508 is applied for any device modifications.
Valid device versions for safety-related use:
4.1.1 Order codes
Feature Designation Option selected
– Order code 5H3B (Promag H 300)
5P3B (Promag P 300)
5W3B (Promag W 300)
000 Nominal diameter All
010 Approval; transmitter + sensor All
015 Power supply All
020 Output; input 1
1)
• Option BA "4-20mA HART"
• Option BB "4-20mA + Wireless HART"
• Option CA "4-20mA HART Ex-i passive"
• Option CB "4-20mA Ex-i + Wireless HART"
• Option CC "4-20mA HART Ex-i active"
021 Output; input 2 All
022 Output; input 3 All
030 Display; operation All
040 Housing All
050 Electrical connection All
060 Liner All
070 Process connection All
075 Electrodes All
080 Calibration flow All