Proline Promag H 300
Endress+Hauser 51
Sensor flange connection
G
F
K
H
E
Z
Z Z-Z
L
A
B
D
M
C
B/2
B/2
E
2
E
2
A0017657
 35 Front view without process connections
DN A B C D E F G H K L M
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
2 62 41.6 34 9 24 42 43 8.5 6 4 M6
4 62 41.6 34 9 24 42 43 8.5 6 4 M6
8 62 41.6 34 9 24 42 43 8.5 6 4 M6
15 62 41.6 34 16 24 42 43 8.5 6 4 M6
25 72 50.2 44 26 29 55 56 8.5 6 4 M6
F
E
G
H
Z–Z
D
C
B
A
Z
K
Z
L
A0005528
 36 Front view without process connections
DN A B C D E F G H K L
90°
±0.5°
60°
±0.5°
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] Tapped holes
40 99.7 85.8 71.0 48.3 34.8 M8 12 17 4
50 112.7 98.8 83.5 60.3 47.5 M8 12 17 4
65 127.7 114.8 100.0 76.1 60.2 M8 12 17 6
80 140.7 133.5 114.0 88.9 72.9 M8 12 17 6