Proline Promag P 200
30 Endress+Hauser
Nominal diameter ASME
[mm] [in] Pressure rating [lbs]
65 2 ½ Class 150 –
80 3 Class 150 27.6
100 4 Class 150 32.0
125 5 Class 150 –
150 6 Class 150 52.9
200 8 Class 150 95.9
Measuring tube specification
Nominal
diameter
Pressure rating Process connection internal diameter
EN
(DIN)
ASME AS 2129 AS 4087 JIS PFA PTFE
[mm] [in] [bar] [psi] [bar] [bar] [bar] [mm] [in] [mm] [in]
15 ½ PN 40 Class 150 – – 20K – – 15 0.59
25 1 PN 40 Class 150 Table E – 20K 23 0.91 26 1.02
32 – PN 40 – – – 20K 32 1.26 35 1.38
40 1 ½ PN 40 Class 150 – – 20K 36 1.42 41 1.61
50 2 PN 40 Class 150 Table E PN 16 10K 48 1.89 52 2.05
65 – PN 16 – – – 10K 63 2.48 67 2.64
80 3 PN 16 Class 150 – – 10K 75 2.95 80 3.15
100 4 PN 16 Class 150 – – 10K 101 3.98 104 4.09
125 – PN 16 – – – 10K 126 4.96 129 5.08
150 6 PN 16 Class 150 – – 10K 154 6.06 156 6.14
200 8 PN 10 Class 150 – – 10K 201 7.91 202 7.95
Materials Transmitter housing
• Order code for "Housing", option C: aluminum coating AlSi10Mg
• Window material: glass
Transmitter cable entries
Order code for "Housing", option C "GT20 two-chamber, aluminum coating"
Electrical connection
Type of protection Material
Cable gland M20 × 1.5 • Non-Ex
• Ex ia
• Ex ic
Plastic
• Ex nA
• Ex tb
Nickel-plated brass
Thread G ½"
via adapter
For non-Ex and Ex
(except for CSA Ex d/XP)
Nickel-plated brass
Thread NPT ½"
via adapter
For non-Ex and Ex
Sensor housing
Aluminum coating AlSi10Mg
Measuring tubes
Stainless steel 1.4301/304 or 1.4306/304L; for flanges made of carbon steel with Al/Zn protective coating