Proline Promag P 200
6 Endress+Hauser
Nominal
diameter
Recommended
flow
Factory settings
min./max. full scale value
(v ~ 0.310 m/s/
Full scale value current
output
(v ~ 2.5 m/s)
Pulse value
(~ 2 pulse/s)
Low flow cut off
(v ~ 0.04 m/s)
[mm] [in] [dm
3
/min] [dm
3
/min] [dm
3
] [dm
3
/min]
150 6 20 to 600 m
3
/h 150 m
3
/h 0.03 m
3
2.5 m
3
/h
200 8 35 to 1 100 m
3
/h 300 m
3
/h 0.05 m
3
5 m
3
/h
Flow characteristic values in US units
Nominal
diameter
Recommended
flow
Factory settings
min./max. full scale value
(v ~ 0.3/10 m/s
Full scale value current
output
(v ~ 2.5 m/s)
Pulse value
(~ 2 pulse/s)
Low flow cut off
(v ~ 0.04 m/s)
[in] [mm] [gal/min] [gal/min] [gal] [gal/min]
½ 15 1.0 to 27 6 0.05 0.10
1 25 2.5 to 80 18 0.2 0.25
– 32 4 to 130 30 0.2 0.5
1 ½ 40 7 to 190 50 0.5 0.75
2 50 10 to 300 75 0.5 1.25
– 65 16 to 500 130 1 2
3 80 24 to 800 200 2 2.5
4 100 40 to 1 250 300 2 4
– 125 60 to 1 950 450 5 7
6 150 90 to 2 650 600 5 12
8 200 155 to 4 850 1 200 10 15
To calculate the measuring range, use the Applicator sizing tool (® ä 37)
Recommended measuring range
"Flow limit" section (® ä 25)
Operable flow range
Over 1000 : 1
Output
Output signal Current output
Current output
4-20 mA HART (passive)
Resolution
< 1 µA
Damping
Adjustable:0.0 to 999 s
Assignable measured
variables
• Volume flow
• Mass flow