Device Functions Proline t-mass 65 5 Group QUICK SETUP
Endress+Hauser 15
!
Note!
The display returns to the QUICK SETUP cell if you press the ESC key combination (
X) during
programming of a parameter anywhere in the menu.
QUICK SETUP - COMMISSION
Use the O or S key at the prompt “QS-COMMISSION NO” and the device access code entry
appears. Enter the device access code “65” and press F; programming is enabled. The prompt “QS-
COMMISSION NO” appears. Use the O or S key to change NO to YES and press F.
LANGUAGE
Use the O or S key to select the required language and continue with F.
PRE-SETTING
SYSTEM UNITS
PIPE TYPE
SELECT OUTPUT
Automatic configuration of the display
The Quick Setup is now complete.
!
Note!
The function UNIT LENGTH is only available if an insertion type sensor is in use.
The function PIPE TYPE is only available if an insertion type sensor is in use. For more
information, see function group SENSOR DATA.
The gas process pressure must be entered for all device types in the function PROCESS PRESSURE
except in case of a remote pressure input being used. For more information, see function group
PROCESS PARAMETERS.
m s: see previous page
m Select ACTUAL SETTINGS to continue programming the device and go to the next level or
select DELIVERY SETTINGS to reset the device. The device restarts and returns to the Home
position.
ACTUAL SETTINGS are the actual programmed parameters in the device
DELIVERY SETTINGS are the programmed parameters (factory settings plus customer
specific settings) originally delivered with the device
Select required system unit function and carry out parameterization or select QUIT to return to the
QUICK SETUP function if no further programming is required.
n Only units not yet configured in the current setup are available for selection in each cycle.
o The “YES” option remains visible until all the units have been configured.
“NO” is the only option displayed when no further units are available.
p Select the type of pipe for setting up the insertion sensor.
Select CIRCULAR for round pipes or RECTANGULAR for duct systems.
Use internal dimensions only.
Select output type and parameterize available options or select QUIT to return to QUICK SETUP
function.
q Only the outputs not yet configured in the current setup are offered for selection in each cycle.
Additional outputs are available if fitted on the device.
r The YES option remains visible until all the outputs have been parameterized. NO is the only
option displayed when no further outputs are available.
s The “automatic parameterization of the display” option contains the following basic set-
tings/factory settings:
YES: main line = MASS FLOW, additional line = TOTALIZER 1
NO: The existing (selected) settings remain.