Operation options RIA14
14 Endress+Hauser
1. Remove the housing cover
2. Remove the display
3. The operating keys on the device are accessible.
4. Configure the device via the operating keys.
5. Position the display at the desired angle.
6.2.1 Navigation
The operating panels are divided into 2 levels.
Menu: Various menu items can be selected in the menu level. The individual menu items
are a summary of the associated operating functions.
Operating function: An operating function can be viewed as a summary of operating
parameters. The operating functions perform the actual operation or configuration of the
device.
Operating keys:
"E" key: Enter the programming menu if the "E" key is pressed for longer than 3 seconds.
• Select operating functions.
• Apply values.
• If the "E" key is pressed for longer than 3 seconds, the display returns directly to the
Home position. You are first asked if the data entered until now should be saved.
• Save data entered.
"+ / -" selection keys:
• Select the menus.
• Configure parameters and numerical values.
• Once the operating function has been selected, the "+" or "-" keys are used to enter the
value or change the setting.
If the keys are pressed for longer, the numbers change with increasing speed.
For the "program name" and "program version" operating items, the display is scrolled
horizontally when the "+" or "-" keys are pressed as these items (7-digit) cannot be
shown completely in the 14-segment display.
6.2.2 Programming in the operating menu
E
E
E
E
E E E
7.
6.
5.
1.
2.
3.
4.
+
_
+
_
+
_
E
E
> 3 s
_
+
> 3 s
Menu
Operating function
A0051891
9 Programming the field indicator
1. Enter the operating menu