Overview
1-2 Introduction
Overview
TheA2H12424PandA2H12448ParestackableFastEthernetswitches,whichcanbe
adaptedandscaledtohelpmeetyournetworkneeds.Theseswitchesprovidea
managementplatformanduplinktoanetworkbackboneforastackedgroupofupto
eightA2switches.ThetwobuiltinSmallForm
Pluggable(SFP)interfaceslotsprovide
youwiththeoptionofinstallingMiniGBICsfor1000BASESX/LX/ELXfiberoptic
connectionsand1000BASETcopperconnections.
TheswitchesalsosupporttheuseofaredundantDCpowersupplytohelpprevent
downtimeduetoaninternalpowersupplyfailureintheswitchor
ACpowersource.
YoucaninstalltheSecureStackA2
onaflatsurfaceorintoastandard19inchrackwith
usersuppliedmountinghardware,andconfiguretheSecureStackA2functionsusingthe
WebViewapplication,CLIswitchingcommands,and/orSNMP.
A2H124-24P and A2H124-48P
TheA2H12424P(Figure 11)andA2H12448P(Figure 12)haveseveraltypesoffront
panelportconnections,whichinclude:
•RJ45ports(10/100Mbps,100BASETcopperports),24ontheA2H12424Pand48on
theA2H12448P.
•SFPslotslabeledport27and28ontheA2H12424P
and51and52ontheA2H12448P
thatprovideyouwiththeoptionofinstallingSmallFormPluggable(SFP)
MiniGBICsfor1000BASESX/LX/ELXfiberopticconnectionsand1000BASET
copperconnections.
1000BASETRJ45stackconnectorswhichcanbeusedinast ackconfigurationaswell
asstandardswitch
portswhenconfiguredasastandaloneswitch.
•RearpanelRedundantPowerSupplyconnectorusedtoconnecttoaSecureStack
C2RPSPOEpowersupplysystemusingtheappropriatecable(C2RPSPOEcable).
The10/100 Mbpsfixedfrontpanelportscanoperateineitherhalfduplexorfullduplex
mode,asdeterminedby
AutoNegotiation.
Caution: The A2H124-24P and A2H124-48P are PoE-compliant devices. Do not connect
a SecureStack C2 Redundant Power System (C2RPS-SYS) to the power connector.
Otherwise, damage to the device may result.
Precaución: Los dispositivos A2H124-24P y A2H124-48P cumplen con el estándar PoE
(power over ethernet). No conecte una fuente de poder redundante (RPS) SecureStack
C2 (C2RPS-SYS) al cable de corriente. De lo contrario, el dispositivo puede dañarse.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack A2 A2H124-24P and is the answer not in the manual?

Enterasys SecureStack A2 A2H124-24P Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack A2 A2H124-24P
CategoryNetwork Router
LanguageEnglish

Related product manuals