19
Stove Operation - Timer Control
sTarT-uP sequenCe:
1. Switch the power “ON” by pushing the start-up switch once only.
2. Turn the dial-a-fire knob to the 12 o’clock position. (Lower grade pellets may need a higher
setting on the feed rate). NOTE: Unit will take longer to light if the hopper has been completely
emptied or is the first fire up.
3. Wait until the fire is established, then turn dial-a-fire knob to the desired heat output. The stove may
not be able to stay burning in the BLUE ZONE if poor quality wood pellets are being used. Adjust the
slider-damper to the appropriate setting.
4. If the stove should shut off after fifteen (15) minutes and there is still a fire in the firebox – press the
start-up switch once more. If the fire went out, return to step 2 and re-light the stove.
SPECIAL NOTES:
The convection blower may cycle to high automatically depending on the setting of knobs “A” and “B”.
This is a normal safety feature of the unit.
Wood pellets of differing quality may affect the performance of the stove. If the stove has trouble
operating at either end of its range, turn the heat output knob forward or back slightly.
sHuT down:
To turn your stove off, simply turn the HEAT OUTPUT knob (“Knob B”) counter-clockwise until the knob
clicks to the “OFF” position. This will stop the feed of pellets.
The blowers will continue to run and cool the stove. When cool enough, the stove will shut down.
DO NOT unplug unit while combustion fan is operating; this may lead to smoke escaping
from the stove.