51
Troubleshooting
THe sTove keePs going ouT:
Ensure
the slider/
damper is in
the correct
position.
Refer to trouBleShooting - the
auger motor Will not FunCtion
normally and trouBleShooting -
the ComBuStion (exhauSt) motor
Will not FunCtion normally.
If the stove goes out and there are no pellets in the liner, the auger is stopping.
The stove goes out and there are partially burned pellets left in the burn pot liner, the stove has shut
down due to a lack of air, poor quality pellets exhaust temperature, or power failure.
The stove goes out and leaves fresh unburned pellets or cigarette-like ashes in the burn pot liner, the
fire is going out before the exhaust temperature sensor shuts off.
Timer Control Only: Turn
the Dial-a-Fire up slightly
(poor quality pellets will
require slightly higher
settings).
Circuit Board Only:
Turn the Heat Level up
slightly (poor quality
pellets will require
slightly higher settings)
Circuit Board Only:
Set the auger
trim till the #1
and #5 lights are
illuminated.
Check to see if the stove needs a more complete
cleaning. Refer to the routine Cleaning and maintenanCe in
the unit’s corresponding Owner’s Manual.
Did the power
go out?
Did
the
power
go
out?
Timer Control Only:
Turn the Dial-a-Fire
up slightly (poor
quality pellets will
require slightly
higher settings).
Circuit Board Only:
Turn the Heat Level
up slightly (poor
quality pellets will
require slightly
higher settings)
Does the motor’s armature try to
spin though the auger gear box
does not turn?
The auger is jammed. Try to break apart jam by
poking at the jam through the drop tube. If this fails
then empty the hopper and remove the auger cover.
**Remember to re-seal the auger cover after
installation**
YES
THe auger ligHT FlasHes BuT THe auger does noT Turn aT all: