161
Section 11: Engraving
Machine Calibration /
Maintenance
In This Section
ļ Config and Calibration Settings
Calibration Settings Using the Keyboard
There are a number of factory settings that normally only need to be set once at the
factory to calibrate the system.
The numerical range of adjustment is shown in the table below. Each single digit
change is equal to a half thousandth of an inch - .0005ā (0.00125 mm) (except the
Laser and Stamp Match values, which are in pixels). For example, changing the X-
Home position value from 350 to 395 would move the X-Home position 0.0225
inches (0.55 mm) to the right.
Because the adjustment increments are so small it may be easier to think of the
change as a two digit change is equal to 0.001 inch.
Config
The Config key takes you into the factory settings that do not normally need to be
reset by the end user. These functions are listed below.