EPSON Stylus COLOR 680/777/777i Revision B
Disassembly and Assembly Disassembly 83
4.2.8 HP/PE Sensor removal
1. Remove the Housing from the printer. (Refer to Section 4.2.1.)
2. Remove the LD roller from the LD roller shaft holder. (Refer to Section 4.2.7.)
3. Remove HP detection lever from the LD roller shaft holder and disconnect the
cable from the sensor connector.
Figure 4-29. Removing the HP detection lever
4. Release the two fixing hooks for the sensor from the LD roller shaft holder and
remove the sensor.
Figure 4-30. Releasing two fixing hooks for the sensor
HP/IC detection lever
HP/PE sensor
Two fixing hooks