2). Ground continuity check
Testing apparatus: Multimeter (with sensitivity down to 0.1 )
Multimeter settings
3). Illumination check
Test conditions: Input a PC or video signal to the projector and check the illumina-
tion for about 5 minutes.
Evaluation: Projector should operate normally with no smoke or fire.
Check Item Tool Standard
Ground continuity check Multimeter
Should be no resistance
(0.5 or less)
a
b
c
(1)
1. Turn on the power switch.
2. Set the range selection switch to .
3. Connect the black lead wire to the COM terminal.
4. Connect the red lead wire to the V//Hz terminal.
5. Check that the resistance at (1) in the diagram below is
0.5 or less.
Display
DC/AC, SW
Power supply
lines
Exposed metal part of projector
Range selec-
tion switch
Terminals
V, , HzCOM
Projector AC inlet
Computer IN connector