EPSON Stylus Pro 7600/9600 Revision A
Disassembly & Assembly Disassembly and Assembly of Circuit Boards 206
4.7.2 AC Inlet
1.
Remove the Rear Cover. (p.166)
2. Disconnect CN001 from the Power Supply Board.
(See Figure 4-81)
3. Remove the one screw (M4
×
8) and toothed washer (M4) fastening the AC Inlet
Ground Cable.
4. Push the hooks (one top and two bottom hooks) and remove the AC Inlet from the
holder.
(See Figure 4-82)
Figure 4-81. Removing the AC Inlet Holder
Figure 4-82. Removing the AC Inlet
C A U T I O N
Unplug the AC power cable and wait at least five minutes before
removing the Power supply Board to make sure there is no residual
power left in the board's capacitors.
Install the AC Inlet in such an orientation that the ground cable
side is positioned up.
Up: Ground cable
CN001
Screw (M4×8), toothed washer
Ground cable
AC Inlet Holder
AC Inlet Holder
AC Inlet
Hook ×1
Hooks ×2

Table of Contents