EPSON Stylus Pro 7600/9600 Revision A
Adjustment Mechanism Adjustment 267
5.3.5 Cover Sensor ASSY Mounting Position Adjustment
When removing/replacing the Cover Assembly or the Front Cover, verify the sensor
operation using the Self-Diagnostic mode as described below.
NOTE: For disassembly and assembly procedure, refer to “Cover Sensor ASSY”
(p.197).
1. Remove the Tube cover.
See
“Cover Sensor ASSY” (p.197)
.
2. Start the Self-diagnostic Function:
Power OFF
[Paper Feed
]
+
[Paper Feed
]+[Cut/Eject] Power ON
3. Display “Test: Sensor”:
[SelecType >]
[Paper Feed
] x2
4. Display “Sen: Cover”:
[SelecType >]
[Paper Feed
] x1
5. Open and close the Front Cover, checking the LCD to make sure the message changes
depending on the Front Cover position.
6. If the correct message does not appear or any other message appears, verify the Cover
Sensor is installed correctly and check the operation again.
Figure 5-68. Adjusting the Cover Sensor ASSY Mounting Position
Table 5-31. Cover Sensor Assembly Check
Front Cover LCD Message
Open Sen: Cover Open
Close Sen: Cover Close
C H E C K
P O I N T
Acceptance Criterion:
The timing for cover opening is such that there is no gap between
the front cover and the printer body which permits entrance of your
finger.
Cover Sensor ASSY