5.2.3 Self-Diagnostics
This section gives detailed descriptions of the items in Table 5-2, “Service
Parts & Required Adjustments,” on page 158.
5.2.3.1 Entering Self-Diagnostic Mode
1. Push down the Release Lever to the Lock position.
2. Press the following buttons on the Control Panel while turning on the
printer.
Paper Feed ↓ + Cut/Eject + Cleaning
3. When "Check: Test" appears on the LCD, the printer has entered the Self-
Diagnostic mode.
Use the Control Panel buttons to activate a Self-Diagnostic function, as
described in the table below.
To exit the Self-Diagnostic mode, turn off the printer.
Figure 5-1. Self-Diagnostic Controls
Table 5-3. Self-Diagnostic Mode Controls
Normal
Function
Self-Diagnostic
Function
Meaning
Pause Return up one
level
Moves up one level (without selecting at item).
SelecType Next menu Displays the next menu.
Paper Source Previous menu Displays the previous menu.
+
(Paper Feed
↑)
Next item or value Displays the next item or increases the value
of the item shown on the LCD.
-
(Paper Feed
↓)
Previous item or
value
Displays the previous item or decreases the
value of the item shown on the LCD.
Cut/Eject Enter Selects/activates the item.
Power
Operate
Sheet
Paper Out
Roll
Cutter Off
Roll
Auto Cut
Cleaning
3 sec.
Enter
Cut /Eject
_
Paper Feed
+
Item
Paper Source
SelecType
Reset
3 sec.
Pause
Ink Out
KC LCMLMY
To next or
previous
menu
To next or
previous
item
Selects or
activates
the item
To next or
previous
menu