TITLE
SHEET
REVISION
NO
SHEETNEXT
59 60
A
TM-T81
Specification
(STANDARD)
DLE DC4 fn a b (fn = 2)
[Name] Execute power-off sequence
[Format] ASCII DLE DC4 fn a b
Hex 10 14 fn a b
Decimal 16 20 fn a b
[Range] fn = 2
a = 1
b = 8
[Description] Executes the printer power-off sequence and transmits the power-off notice.
Stores the values of the maintenance counter.
Sets the interface to BUSY.
Sets the printer to standby mode.
[Notes] Take the following into consideration:
If the received data includes a data string matching this command, the printer
performs the command. Users must consider this.
For example: Graphic data might accidentally include a data string matching this
command.
Do not embed this command within another command.
For example: Graphic data might include this command.
This command does not shut the power off. The operator must turn off the power
after receiving the power-off notice.
If this command is encountered, the printer will not continue to process anything. To
recover the printer to print again, it is necessary to turn the power on again or execute
a hardware reset.
[Reference] Appendix G

Table of Contents

Other manuals for Epson TM-T81

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson TM-T81 and is the answer not in the manual?

Epson TM-T81 Specifications

General IconGeneral
Print MethodThermal line printing
AutocutterYes
InterfaceUSB, Ethernet
Dimensions140 mm (W) x 199 mm (D) x 146 mm (H)
Power SupplyAC 100 V - 240 V, 50 Hz - 60 Hz
Paper Width79.5 ±0.5 mm