16.4EXHAUST PIPE REMOVAL
You must wait at least 15 minutes after stopping the engine.
You need to remove the seat, rear fender and footrest plate,
before you take off the exhaust pipe.
Loosen the two exhaust pipe bolts that fixed on the engine.
WarningDO NOT service the exhaust pipe while they are hot.
Remove the exhaust pipe bolts mounting on the frame
below the seat.
Remove the exhaust pipe carefully.
Screws
Nuts
Bolts