85
10-2 Precautions in Operation
General information
y Refer to chapter 17: The troubleshooting and inspection of alternator
y Refer to chapter 17: The service procedures and precaution items of starter motor
Specification
Item Standard value (mm) Limit (mm)
ID of starting clutch gear 25.026~25.045 25.100
OD of starting clutch gear 42.175~42.200 42.100
Torque value
Flywheel nut 5.0~6.0kgf-m
Starting clutch hexagon bolt 1.0~1.4kgf-m with adhesive
8 mm bolts 0.8~1.2kgf-m
12 mm bolts 1.0~1.4kgf-m
Tools
Special tools
A.C.G. flywheel puller: SYM-3110A00
Universal holder: SYM-2210100

Table of Contents