EVCO S.p.A.
EVBOX1 | Installation guide ver. 2.0 | Code 144BOX1E204
page 78 of 100
PARAM. MIN. MAX. U.M.
EVB1204
EVB1214
EVB1206
EVB1216
EVB1226
EVB1236
EVB1246
EVB1256
DATA LOGGING EXTENSION
Sd0 1 30 min
not
avail.
30
not
avail.
30
not
avail.
not
avail.
not
avail.
30 writing interval in “HACCP” mode
Sd1 1 30 min
not
avail.
1
not
avail.
1
not
avail.
not
avail.
not
avail.
1 writing interval in “service” mode
Sd2 1 240 min
not
avail.
60
not
avail.
60
not
avail.
not
avail.
not
avail.
60 duration of the “service” writing mode
Sd3 0 1 - - - -
not
avail.
0
not
avail.
0
not
avail.
not
avail.
not
avail.
0
enabling the auxiliary 3 temperature probe
1 = YES
Sd4 0 1 - - - -
not
avail.
0
not
avail.
0
not
avail.
not
avail.
not
avail.
0
enabling the writing of the room temperature value
1 = YES
Sd5 0 1 - - - -
not
avail.
1
not
avail.
1
not
avail.
not
avail.
not
avail.
1
kind of decimal separator
0 = comma
1 = point
Sd6 0 2 - - - -
not
avail.
1
not
avail.
1
not
avail.
not
avail.
not
avail.
1
kind of auxiliary 2 temperature probe and auxiliary 3
temperature probe; also look at P0
0 = reserved
1 = NTC
2 = Pt 1000