u
Section
10
ON/OFF
SWITCH
REPLACEMENT
10.1
General
The
ON/OFF
switch
is
most
often
damaged
as
a
result
of
being
used
as
a
"handle"
or
"grip"
for
removing
the
unit
out
of
the
aircraft.
The
proper
way
to
remove
the
Argus
from
the
aircraft
is
as
follows:
1.
Loosen
the
two
top-most
phillips
head
screws
approximately
3
full
turns
counter
clockwise.
2.
Apply
pressure
to
these
two
screws
to
release
the
clamp
fixture.
3.
Insert
a
removal
tool
or
a
dull-edged
flat-blade
screwdriver
into
both
slots
in
the
sides
of
the
bezel,
and
apply
light
pulling
pressure
to
remove
the
Argus
from
its
tray.
In
order
to
replace
the
ON/OFF
switch,
you
must
completely
disassemble
the
Argus.
The
instructions for
replacing
this
switch
in
the
model
3000
and
5000
are
combined,
since
the
two
models
are
so
similar.
The
instructions
for
replacing
this
switch
in
the
model
7000
are
given
separately.
NOTE
I
|
When
removing
the
screws,
take
note
of
their
location,
as
it
is
important
that
they
are
replaced
M
correctly.
M
10.2
3000
and
5000
ON/OFF
Switch
Replacement
The
ordering
part
number
for
the
ON/OFF
switch
assembly
is
#300167.
Be
sure
to
specify
Argus
model.
^
Necessary
Tools:
Small
phillips
head
screwdriver
Allen
key
(0.050")
I
!
Small
open
end
wrench
(5/16")
Disassemble
The
Argus
LJ
1.
Remove
the
screws
from
the
right
side
panel
(panel
nearest
the
operating
controls).
Note
the
position
of
smaller
screws
versus
larger
ones.
Remove
this
panel
to
expose
the
CPU
in
the
3000
j
or
the
database
board
in
the
5000.
If
the
Argus
is
a
model
3000,
skip
step
2
below.
U
2.
In
the
model
5000,
two
pairs
of
small
pins
and
two
28
pin
connectors
on
the
component
side
of
the
U
database
board
connect
it
to
the
underlying
CPU
board.
The
connectors
are
located
near
the
front
panel
bezel.
Gently
pull
on
the
database
board,
lifting
it
up from
the
back
of
the
unit
and
wiggling
it
gently
to
disengage
it
from
the
connector
on
the
CPU
board.
Remove
the
database
board
from
j
I
the
unit's
housing.
3.
Remove
the
left
side
panel
in
the
same
manner
as
you
removed
the
right
side panel.