EasyManuals Logo

Evoqua IONPURE IP-MXM30 User Manual

Evoqua IONPURE IP-MXM30
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
IONPURE
®
MX CEDI Modules
Page 20 of 32 IP-MAN-MX-Rev E
Mix the required amount chemical (from the recipe in Section 6.7) with the water in
the tank. In the case of HCl, additional acid may be required during the recirculation
period.
Open the pump suction and pump bypass valves.
Start the cleaning pump and circulate the solution through the pump bypass to mix the
contents of the tank.
When the solution is well mixed, gradually open the pump discharge valve while
closing the pump bypass valve to adjust the product and reject flow rates to the values
given in Section 6.4, Table 6-1.
Recirculate the solution through the module for 30-60 minutes. Longer contact time
may be desirable in some instances. See Ionpure Service Bulletin 2007-02b. Contact
Ionpure Technical Support if you have further questions.
6.6.3 Return to service
Turn off the cleaning pump.
Check pH of solution in tank. Neutralize if necessary, then drain the CIP system tank.
Refill the tank with water.
Optional step: make brine solution, circulate through CEDI and then drain tank. This
helps remove chemicals from CEDI and may speed rinseup to quality.
Refill tank with water, circulate through CEDI and then drain tank.
Close the cleaning pump discharge valve. Keep product and reject lines directed to
drain and disconnect the CIP equipment from the CEDI system.
Turn on the feed water supply to the CEDI system. Gradually allow RO product water
to flow through the module to drain.
Flush residual cleaning solution from the CEDI system for five minutes, then apply the
DC power.
Flush water to drain with DC power on until reaching desired CEDI product water
quality, then send product water to use.
6.7. Cleaning Solution Recipes
Use appropriate PPE when using any of below chemicals for
cleaning CEDI modules. Consult SDS from chemical supplier.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Evoqua IONPURE IP-MXM30 and is the answer not in the manual?

Evoqua IONPURE IP-MXM30 Specifications

General IconGeneral
BrandEvoqua
ModelIONPURE IP-MXM30
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals