IONPURE
®
MX CEDI Modules
Page 19 of 32 IP-MAN-MX-Rev E
6.5. Chemical Cleaning and Sanitization Precautions
Avoid direct skin contact with cleaning chemicals. Use appropriate
Personal Protective Equipment (PPE), such as safety glasses,
gloves and protective clothing.
Flush all hoses and tank with clean water BEFORE adding chemicals.
Pressure-test CIP system and connecting hoses with water before adding chemicals
to tank.
To reduce the possibility of chemical sprays, relieve the pressure in chemical lines
before disassembly.
Do not run a cleaning solution through the system when DC power is applied to the
module. Make sure the DC power is off before cleaning.
Follow the manufacturer’s chemical safety instructions on the
container labels.
Check the pH level in any solution before letting it flow to the drain. Follow all discharge
limitations.
6.6. Typical Procedure for Cleaning or Sanitization
NOTE: The following cleaning procedure is based on the CIP system shown in Figure 6-
1. If your CIP system is different, you may need to adapt this procedure.
6.6.1 Preparation
Turn off the DC power supply.
Drain most of water from the CEDI system.
Close the CEDI system feed valve and product valve.
Connect the discharge of the cleaning pump to the MX system feed CIP connection.
Connect the CEDI system reject and product CIP connections to the cleaning tank.
Verify that all piping connections are secure.
Close cleaning pump discharge valve until ready to pump the cleaning solution into
the MX system.
6.6.2 Cleaning
Follow the instructions in Section 6.6.1 (above) to prepare the MX system for chemical
cleaning.
Make sure the tank drain valve is closed.
Fill the tank with the required amount of water, according to the applicable solution
recipe in Section 6.7.
Circulate water through the CEDI system, check CIP apparatus for leaks, fix any leaks
if present.