IONPURE
®
MX CEDI Modules
Page 7 of 32 IP-MAN-MX-Rev E
NOTE: The warranty may be void if installation or operation instructions contained in
this manual are not followed exactly.
This manual describes the installation, operation, and routine maintenance of the MX
module. It also contains information on basic troubleshooting (Section 7).
IONPURE strongly recommends all users read the entire contents of the manual. If
the MX module is not operating properly after going through the basic troubleshooting
exercises, contact your Local Service Provider.
1.3. Installation Precautions
Do not open the MX CEDI module. Opening the module will void the warranty and do
irreversible damage
During operation, the electrode wiring inside the module junction boxes may be at high
voltage and present a shock hazard. Therefore, before opening the junction box,
confirm that DC power has been disconnected and locked out according to standard
lockout/tagout procedures.
To eliminate the possibility of electric shock, confirm that all ground wires are properly
connected. Thoroughly read all the information in this manual before operating the
MX module.
The module must be operated within its design specifications for temperature and
humidity.
Metal piping should never be connected directly to the module. Non-metallic piping
or tubing adapters are required.
Pipe sections prepared for installation must be inspected, and be free of debris from
storage or cutting tool particles. This must be done before installation.
Because MX modules have narrow flow distribution channels, plugging by particles
can cause permanent damage. Always install pressure gauges, sampling ports,
sensors, etc. in tee fittings. Do not drill or tap into piping. After installing gauges,
sampling ports, sensors, etc., always flush out the piping before connecting to the MX
module to remove any debris.
Installation of the MX module must be completed in accordance with the procedures
outlined in this manual. If deviations from the prescribed procedures are deemed
necessary to achieve the desired performance, consult your local Service Provider.
1.4. Operating Precautions
Do not apply DC power to the MX module until proper product and reject flows and
pressures have been checked and verified.
Never block-off (dead-head) the MX outlets. Dead-heading the outlets can result in
over-pressurization, causing permanent damage to the module.
Do not operate the module under conditions other than those stated in the module
manual. The prescribed feed water and electrical requirements, and flow
configurations, must be followed at all times. If the feed water quality or the product