IONPURE
®
MX CEDI Modules
Page 11 of 32 IP-MAN-MX-Rev E
In most cases, pre-treating MX module feed water with reverse osmosis (RO) will bring it
within these specifications. Depending on the conditions, however, some sites may
require additional pretreatment. To determine if additional pretreatment is required,
compare the MX feed water (RO Permeate) on site with the feed water requirements
listed below.
Note: Recycling the MX reject to the RO feed will cause the CO
2
load on the MX to
increase, and may have an impact on the product water quality.
2.4.5 Drain Requirements
Place the MX module near a drain that can accommodate at least 100% of the total feed
flow.
2.5. Flow Rates and Pressure Drops
See Appendix A.