EasyManuals Logo

Excell Counting Scale User Manual

Default Icon
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
EXCELL PRECISION CO., LTD.
Counting ZSME200000003
13
2-7 UNIT WEIGHT CALIBRATION
Two methods of unit weight calibration are available depending on the scale
configuration they are either:-
1. Auto Calibration if weight is over 10% of the last sampling value, the scale
will automatically re-calculate the unit weight.
Example:
Say the current unit weight is 2.5g. If the next batch of product of the same
type has a slightly different unit weight say 2.8g, then because the difference
between the to unit weights is greater than 10% the scale will average the two
values and set a new unit weight of 2.65g. If the difference in unit weights are
less than 10% then the unit weight is not re-calculated.
2. Manual Calibration Press
SMPL
key to determine the unit weight.
The Auto Unit Weight calibration is setting is a factory set option. If it is set to off
then the auto unit weight calculation is disabled.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Excell Counting Scale and is the answer not in the manual?

Excell Counting Scale Specifications

General IconGeneral
BrandExcell
ModelCounting Scale
CategoryScales
LanguageEnglish

Related product manuals