EasyManua.ls Logo

Excell Counting Scale - Chapter 3 User Interface Setting; M+ Key Action; Pre-Set Tare

Default Icon
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EXCELL PRECISION CO., LTD.
Counting ZSME200000003
21
CHAPTER 3 USER INTERFACE SETTING
3-1 M+ KEY ACTION
Press Z then 1 twice.
Weight Unit Weight Quantity
X
Press 0 , 1 or 2 to select the required mode
0 = When M+ key is pressed, the display will show the totalised value. Then, the
scale will count back to zero after 3 seconds.
1 = When M+ key is pressed, the display will show the totalised value. Then, the
scale will count back to zero when the CE key is pressed.
2 = When M+ key is pressed, the beeper only will sound and the display wont
show the totalised value.
To exit and save the entry, press the key
3-2 PRE-SET TARE
Press Z then 1 followed by 2
Weight Unit Weight Quantity
X
Press 0 or 1 to select the required mode
0 = Pre-set Tare function is not available when there is an object on the scale.
1 = Pre-set Tare function is available when there is an object on the scale.
To exit and save the entry, press the key

Table of Contents