EX-2001 NC RACER ZSME300000091
36
EXCELL PRECISION CO., LTD.
Start
Check Weighing
Mode Selected
( FUNC.53 setting)
Comparison
occurs at any
time
Comparison occurs
after inputting
external judgment
signal
Auto
comparison
FUNC.53 = 0 FUNC.53 = 1 FUNC.53 = 2
Judgment
Signal Input
N
NET < LO
LO NET
< HIGH
NET HIGH
LO / UNDER
Output
OK / FINAL
Output
HI / OVER
Output
Y
Y
Y
N
N
Input judgment
signal
Lead time count
down of inputting
judgment signal
(FUNC.55 setting)
N
Y
Y
NET > Auto
transmit range
(FUN10 setting)
N
The weight value
is stable
N
Y
Y
NET < LO
LO NET
< HIGH
NET HIGH
LO / UNDER
Output
OK / FINAL
Output
HI / OVER
Output
Y
Y
Y
N
N
Y
NET < LO
LO NET < HIGH
NET HIGH
LO / UNDER
Output
OK / FINAL
Output
HI / OVER
Output
Y
Y
Y
N
N
Y
( One time weighing
comparison occurs after
receiving the external
judgment signal, including the
lead time )
( One time weighing comparison
occurs when the weight of the
object is over Zero and stable )
2 HI , OK , LO Output Procedure