EX-2001 NC RACER ZSME300000091
41
EXCELL PRECISION CO., LTD.
CHAPTER 9 FUNCTION TABLE
GENERAL FUNCTION
SET VALUE
FUNC.NO FUNCTION
PARAMETER DESCRIPTION
DEFAUT
0 ON
FUNC. 0
Tare and Zero
function when
the weight is
unstable
1 OFF
0
0 ON
FUNC. 1
Tare function
with negative
gross weight
1 OFF
0
0ON
FUNC. 2 Key function
0 000
1 111
1OFF
0 000 corresponding
keys from left to right
are
0 000
0 OFF
FUNC. 3
Auto Zero
function
after power on
1
ON
0
FUNC. 4 Zero range
0d
9d
When the weight is in this
range
±(Set value × Min. division)
it displays “0”
0
0 5 Hz
1 4.17 Hz
2 2.5 Hz
3 2.08 Hz
4 1.25 Hz
5 1.04 Hz
6 0.63 Hz
7 0.52 Hz
8 0.31 Hz
FUNC. 5
Weighing Filter
(1)
9 0.26 Hz
4
0 Not use
FUNC. 6
Weighing Filter
(2)
1~5 weak Æ strong
2
TARE
PRINT
ZERO
+
GROSS
NET

Related product manuals