EasyManua.ls Logo

Expert SmartTurn - Sensor Fault (Sensor Defect)

Expert SmartTurn
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Turntable control SmartTurn
Faults
58 Dok-ID:EXPERT-0003-EN-2011
6.3.1 Sensor fault (sensor defect)
Possible causes Measures
Sensor is defective Check sensor and replace if necessary
Position encoder is defective or is not in the
detection range of the sensor
Check the position sensor, replace if necessary
Sensor cable is defective or loose Check the position sensor, replace if necessary
Sensor cable has been inadvertently unscrewed Screw on the sensor cable
Reset fault
NOTE!
Eliminate cause.
Unscrew the cover on the turntable control unit.
Press the reset button for at least 3 s.
System fault LED goes out.
Turn the turntable several times at operating speed.
Press the reset button and the default values will be used for
turntable control.
Pos: 6.10 /S martT ur n/S mar tTur n-Neu-0 2.201 1/6.3. 3 Kurzsc hlus s am aus gang @ 3\ mod_1315561035885_38.doc @ 30187