IN1804 Seamless Scaling Switchers • Installation 19
NOTE: When using shielded twisted pair cable in bundles or conduits, consider the
following:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 meters, where cables are straightened,
aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
Separate twisted pair cables from AC power cables.
Wiring the Contact/Tally Connectors
The CONTACT/TALLY portion of the rear panel on all models contains seven sets of contact
and tally captive screw connectors (numbered 1 through 7), each with two pins labeled
C and T, for contact closure and tally indicator devices. The CONTACT/TALLY panel also
contains a 2-pole captive screw connector with a G (ground) pin and a +V pin that provides
+5 VDC power to the indicator devices connected to the tally (T) ports.
These ports can be used for triggering and feedback associated with the selected input,
for contact-based input switching, and for other triggered functions such as CEC display
control or video mute. Contact/Tally ports are typically used with Extron Show Me (SM)
cables or with external equipment (such as the Extron CCB 30) to control IN1804 functions,
depending on which Contact/Tally port is used.
1
CT
2
CT
3
CT
4
CT
5
CT
6
CT
7
CT GV+
CONTACT
/TALLY
111
444333
222
Figure 14. Contact/Tally Panel
Contact/Tally ports 1 through 4 — (See figure 14,
1
) Each CONTACT/TALLY
connector is labeled with the number of the video input associated with it. Wire a
push button or other contact closure switch to pin C (Contact) and to the shared pin G
(ground,
3
).
If using a tally indicator, connect the indicator device to the shared +V pin (5 VDC,
required for tally devices without a power supply,
4
) and the T (Tally) pin.
In other words, the V+ pin of the switcher connects to the voltage in (anode) of
the indicator, and the T pin connects to the tally output (cathode) of the indicator
device.
NOTE: If the indicator has an internal power supply, it is not necessary to
connect it to the V+ pin. It can be connected directly to the T pin of the
Contact/Tally input connector.
If using an SM cable, see Connecting Using an SM Cable on the next page.
Ports 5 through 7 (configurable via PCS) — (
2
) Wire a push button or other
contact closure switch to pin C and to the shared pin G. If using a tally indicator, connect
the indicator device to the shared +V pin and the T pin.
See the IN1804 Series Help File for instructions on configuring these ports using PCS.