INSTRUCTION MANUAL MT, MA2, MK2, M10 DRIVE UNIT
18
• Side installation
Mounting plate
1
e mounting plate is not manufactured by FAAC.
e measurement from the oor or other permanent entry level to the lower
edge of the mounting plate should be at least 2,550 mm.
e dimensions of the mounting plate should be 200 mm x 400 mm and
it should be at least 8 mm thick. It must be positioned according to the
enclosed assembly drawing. e mounting plate is to be anchored so that it
can withstand a torque of 2,000 Nm.
Example: Siporex wall - through-going M10 bolts are used.
Concrete – 10 mm resin anchor.
Steel building – square tube onto a xed building structure.
e mounting plate is also welded onto the gate surround.
Drive arm
2
Install the drive arm by removing the bolt and washer /
retaining ring on the output shaft from the drive unit and
pressing the arm into place.
en reinstall the bolt and washer.