Digital outputs
Nominal supply voltage + 24 Vdc.
Maximum nominal voltage + 30 Vdc.
Minimum nominal voltage + 18 Vdc.
Output voltage Vout = Supply voltage (Vdc) -3 V
Maximum output current 100 mA
Protection by means of galvanic isolation by optocouplers.
Shortcircuit protection. Place external recovery diodes.
Analog outputs for axes and spindle
Command voltage within ±10 V, 16-bit solution
Minimum impedance of the connected connector 10 K.
Shielded cable should be used.
Ambient conditions
Relative humidity: 30-95 % without condensation.
Operating temperature: between +5 ºC (41 ºF) and +40 ºC (104 ºF) with an average under +35 ºC
(95 ºF).
Storage temperature: between -25 ºC (-13 ºF) and +70 ºC (158 ºF).
Maximum work altitude: Meets the “IEC 1131-2” standard.
Packaging
Meets the “EN 60068-2-32” standard
Vibration
When running 10-50 Hz amplitude 0.2 mm (1g).
While being shipped 10-50 Hz amplitude 1 mm (5g).
Free fall of packaged unit under Fagor ruling 1m.
Electromagnetic compatibility and safety
Refer to the section on safety conditions in the introduction of this manual.
Degree of protection
Central Unit : IP54 for the front panel and IP2X for the rear panel.
Accessible parts inside: IP1X.
Operator panel: IP54
Battery
3.5 V lithium battery
Estimated life: 3 years
As from error indication (low battery) the information contained in the memory will be kept for 10
days maximum, with the CNC off. It must be replaced.
Neither attempt to recharge the battery nor expose it to temperatures over 100 ºC
(212 ºF).
Do not short-circuit the terminals for risk of explosion or combustion.