EasyManua.ls Logo

Fagor 8035-T - Page 51

Fagor 8035-T
470 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...

Installation manual
CNC 8035
CNC CONFIGURATION
CNC structure
1.
(SOFT M: V15.3X)
(S
OFT T: V16.3X)
·51·
Connectors X10, X11, X12
Feedback inputs for the axes
X10 For feedback connection of the first axis.
X11 For feedback connection of the second axis.
X12 For feedback connection of the third axis.
15-pin high density SUB-D type female connectors.
Admits differential TTL and 1Vpp sinusoidal feedback.
The cable shield must be connected to the metallic hood at each end.
Protection at the connectors
It detects over-currents or short-circuits at the feedback of the handwheels, spindle and probe and
it issues the relevant error message.
Pin Signal and function
1
2
3
4
5
6
7
8
A
/ A
B
/ B
I0
/ I0
- - -
- - -
Feedback signals.
9
10
11
12
13
14
15
+5 V
+5 V
GND
GND
100P
- - -
Chassis
Voltage supply for the feedback system.
Shield

Table of Contents

Related product manuals