Installation manual
CNC 8035
MACHINE PARAMETERS
General machine parameters
4.
(SOFT M: V15.3X)
(S
OFT T: V16.3X)
·97·
DIPLCOF (P110)
This parameter indicates whether the CNC takes into consideration or not the additive zero offset
when displaying the coordinates of the axes on the screen and when accessing the POS(X-C) and
TPOS(X-C) variables.
The additive zero offset can be originated as follows:
• With variable PLCOF(X-C), it is possible to set an additive zero offset for each CNC axis from
the PLC.
• With the additive handwheel.
HANDWIN (P111) HANDWHE1 (P112) HANDWHE2 (P113)
HANDWHE3 (P114) HANDWHE4 (P115)
Not being used.
STOPTAP (P116)
Indicates whether the general inputs /STOP (M5001), /FEEDHOL (M5002) and /XFERINH (M5003)
are enabled (P116=YES) or not (P116=NO) while executing function G84, regular tapping or rigid
tapping.
INSFEED (P117)
Sets the tool inspection feedrate.
When accessing tool inspection, the CNC assumes this feedrate as the new one, and it resumes
the execution of the program at the previous feedrate (the one used in the program or set via MDI
while in tool inspection) when tool inspection is over.
If set to "0" (by default), tool inspection will be carried out at the feedrate currently used for machining.
DISTYPE (P118)
Only to be used by Fagor Automation technical personnel.
Value Meaning
0 When displaying the position of the axes referred to home, it only takes into
account the additive offset when displaying the coordinates referred to
machine reference zero.
The coordinate returned by the POS(X-C) and TPOS(X-C) variables takes
into account the additive zero offset.
1 When displaying the position of the axes, it ignores the additive offset.
The coordinate returned by the POS(X-C) and TPOS(X-C) variables
ignores the additive zero offset.
2 When displaying the position of the axes, the CNC takes into account the
additive offset except when showing the Command - Actual -To Go
coordinates.
The coordinate returned by the POS(X-C) and TPOS(X-C) variables takes
into account the additive zero offset.
Default value: 0
Possible values
Between 0.0001 and 199999.9999 degrees/min or mm/min.
Between 0.00001 and 7874.01574 inches/min.
Default value: NO