Digital Brushless AC Servo Drive system - Ref.1609 ACSD-47/80
To assign node number 13 to a drive, the SS selector must be in
the OFF position and the rotary selector NS in the D position (13 in
decimal), which results from the previous formula the node value:
Node = 13+(16x0) = 13
To assign node number 20 to a drive, the SS switch must be in
the ON position and the rotary selector NS in the 4 position, which
results from the formula the node value:
Node = 4+(16x1) = 20
The following diagrams shows the mentioned situations:
All of the possibilities for displaying and modifying parameters, vari-
ables and commands can only be accessed from the master
device and their availability depends on a particular access level.
Examples.
NOTE. Note that to select the node number between 1 and 15,
the SPEED SELECT switch must be in the OFF position.