Loading...
- 15 -
15
Communication Protocols
0x2C
(44)
FAS_
StepAlarmReset
Reset STEP alarm status or release reset.
To make a reset, send ‘reset ONand ‘reset releasesequentially.
Sending : 1 byte
Response : 1 byte
1 byte
Reset ON(1) Reset release(0)
1 byte
Communication status
0x2E
(46)
FAS_
ServoAlarmtype
To request the Alarm type
Sending: 0 byte
Response: 2 byte
Alarm type: No alarm (0) OverCurrent(1) OverSpeed(2)
StepOut(3) OverTemperature(5) BackEMF(6)
MotorConnect(7) MotorPower(9) Inposition(10)
1 byte
1 bytes
Communication status
Alarm type ( 1~ )