TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 68 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
7.2 Editing a selected parameter
7.3 Exit parameter operation mode
Keep the STOP button pressed for approx. 3 seconds in
order to leave the parameter mode and change to the door
mode. The door operation is active when the display shows
for example:
FEIG ELECTRONIC
xxxx Zyklen
1.
By briefly pressing the STOP key on the membrane keypad,
the cursor moves to the right to the stored value (the
parameter is opened) or the preset value is displayed.
P: Offenhalt 1 |
010= 10 s
P: Offenhalt1 |
010= 10s
2.
or
The parameter value is increased with the OPEN button and
reduced with the CLOSE button.
If the value has not yet been saved, a question mark
is displayed after the number or the decimal point
flashes.
P: Offenhalt1 |
010= 9?s
3.
If the STOP key is only pressed briefly, the set value is not
saved and the value is changed to the originally stored value,
i.e. the original value is displayed.
P: Offenhalt1 |
010= 10s
If the STOP key is pressed until the check mark appears or the
decimal point no longer flashes, the changed parameter value
is saved.
P: Offenhalt1 |
010= 9s
4.
If you now press the STOP key briefly, you change to the
display of the parameter name or the cursor jumps back to the
parameterization.
P: Offenhalt1 |
010= 9 s

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Feig Electronic TST FUF2-C and is the answer not in the manual?

Feig Electronic TST FUF2-C Specifications

General IconGeneral
BrandFeig Electronic
ModelTST FUF2-C
CategoryController
LanguageEnglish

Related product manuals